Top Page | Home | Products | Application Data | Support & Service | Contact Us | About Us |
Fluorescence Microplate Reader
MTP-600F / MTP-600Lab
Hardware | Specifications
Variable photometry
Variable photometry Flexible structure enables three detecting mode
  • Dual-Ex / Single-Em mode
  • Single-Ex / Dual-Em mode
  • Single-Ex / Single-Em mode
  • Altitude of light focus is variable supporting both suspended and precipitated sample.
    Self Diagnosis Function
    MTP-600 automatically checks lightfs total light-up time, intensity, and interference filter's status.
    MTP-600 comes with Ex 365, 490 and Em 450, 530 interference filters.
    Each five more additional Em and Ex filter can be installed.
    Note: Wavelength of Ex and Em filter should be different by 40nm or more when those filters are used together.
    Built-in Temperature Control Function
    Temperature setting is selectable among Room Ambient, 50ºC and 45ºC.
    Mixing Function
    Built-in shaker with 3-step mixing intensity and linear or orbital direction of mixing.


    Data Analysis Software is bundled
    Data Treatment Software is bundled.
    Calculation of working curve and cut off, data analysis and accuracy check-up are offered as standard function.
                          Working Curve Calculation
    Scale of Graph (X, Y) : Linear or Log
    Blank setting : At max. 8 points
    Standard Concentration : At Max. 12, with up to 6 replicates
                                Regression Formula
        Linear, Linear through OP and quadratic function
    Logit-Log : Linear, Quadratic, Cubic
    Logistic : 4 and 5-coefficient
    Spline : Linear and Cubic
        B/Bo calculation for competitive ELISA
        Positive/Negative judgment
                                    Cut off Calculation
        Linear, Cut off calculation formula
        Data Analysis Data Convert, Factor multiplication, Standard curve
    Data treatment : ± judgment, Data aliquot level judgment, Row-by-row/Line-by-line subtraction
    Accuracy check-up : Resulting data (Row-by-row, Line-by-line and whole plate) in form of average, CV% and SD
                          Hardware Requirements
    OS : Windows 95 or later OS
    Memory : 16MB or more(24MB or more is recommended)
    Hard Disc Drive Space : 5MB
    Media : CD
                                    Maneuver Indicator
        LED indicators on operation panel visualize selected items. Combination of setting items are easy to understand.
    MODE : Selection of Endpoint or Kinetics
    SENS : 1Selection of detecting-sensitivity range
    MIX : Selection of mixing time



    Copyright(C) CORONA ELECTRIC Co.,Ltd. All rights reserved.